Free Shipping
HVAC Express Parts

Mini Split Control Boards and Modules

Replacement mini split control boards (PCBs, or circuit boards) for ductless systems and heat pumps: main boards, inverter module subassemblies, electronic control box assemblies and data transfer boards for 115V, 220V and 230V units. They are used in select Midea, Cooper & Hunter, MrCool and Pioneer models. The guide below shows how to match one by part number.

228 products
123…5

Buying guide

How to choose a replacement mini split control board

Start with the board you are replacing, then confirm the unit, the board type, the voltage and the cause of the failure.

Find your part by model
Outdoor main control board subassembly with heatsink for US1-KFR67W/BP2N1W-CA01
  1. 1

    Read the label on the old board

    Most listings name the unit model first, then the board's part numbers, for example US1-KFR35W/BP3N1-X230 17122000048121 / 17222000033256. Write down every number on the board's sticker and photograph the board in place before you unplug anything, so each connector goes back to the same spot.

    • Unit modelfirst in most titles
    • Part numbersafter the model
    • Photobefore you unplug
  2. 2

    Match the unit model and the board type

    One unit model can use several different boards. Some listings are marked single only or multi only, and some are a V2 revision. Choose the listing whose type and part number match the board you removed, not just the model on the rating label.

    • Main boardindoor or outdoor
    • Inverter moduleoutdoor subassembly
    • Control boxcomplete assembly
    • Data transfersingle or multi only
  3. 3

    Check voltage and system type

    Boards here are listed for 115V, 220V and 230V systems, and the board must match the voltage on the unit's rating label. Ducted units have their own boards, listed as Duct MCB, so order one only if your unit is ducted. Compare the product photos with your board, including the connector layout.

    • 115V · 220V · 230Vsupply ratings listed
    • Duct MCBducted units only
    • V2revised boards
  4. 4

    Confirm the board is the failed part

    A board often gets blamed for a fault somewhere else. Read the error code, then have a technician check the sensors, wiring and fan motors before you order. A shorted motor can take out a new board the same way, and a compressor fault can look like an inverter board failure. Turn the power off at the disconnect first.

    • Error coderead it first
    • Fan motora short can kill a board
    • Compressorcan mimic a board fault
ASM135D23UFZ DC inverter rotary mini split compressorCompressors DC inverter rotary, fixed-speed rotary and scroll ZKFP-20-8-6-7 indoor brushless DC fan motorFan motors brushless DC motors for indoor and outdoor fans

Before you order

  • Copy the part number from the old board's sticker.
  • Take the unit model and voltage from the rating label.
  • Know the board type: main board, inverter module, control box or data transfer board.
  • Have a technician read the error code and test the other parts.

FAQ

Mini split control board questions

Short answers based on the product pages in this category. Not sure which part fits? Contact us with your unit model and the part number from the old part.

Finding the right board

  • How do I find the right control board for my mini split?

    Start with the sticker on the old board and copy every number on it. Most listings show the unit model and the board part numbers, so match both. If the sticker is unreadable, enter the model from the unit's rating label in the Parts Finder.

  • Can I use a board with a different part number?

    Only if the listing shows your unit model and the board type matches. Boards for the same unit can differ: single-zone and multi-zone versions, V2 revisions and duct boards. If the numbers do not line up, call (786) 223-7655 before you order.

  • Is the board for the indoor or the outdoor unit?

    Indoor and outdoor units have separate boards. Match the model on the rating label of the unit the board came out of to the model at the start of the listing title.

Voltage, faults and returns

  • Does the board voltage have to match my unit?

    Yes. Boards here are listed for 115V, 220V or 230V systems. Match the voltage on the unit's rating label and never install a board rated for a different supply, even if the connectors look the same.

  • What if the new board does not fix the problem?

    Then the fault may be elsewhere, which is why a technician should test the system first. Parts can be returned within 30 days if they were not installed, connected or used, and a connected board counts as used. See the refund policy.

  • Do I need a technician to replace a mini split control board?

    A board swap is electrical work: turn the power off at the disconnect and let stored charge drain first. A technician can read the error code, test the fan motors and sensors, and confirm the board is the failed part.